Corrosion Resistance of Concrete with High Fly Ash Content
Abstract: It is established that the coefficient of corrosion resistance of the concrete samples, the composition of which contains fly ash of thermal power plants to replace a portion of Portland cement is higher than that of the control composition. Processing of fly ash in electric separator allows increasing quality: improve the particle size and to reduce the content of unburned carbon (PPP). When the content in a concrete mix of ash, selected from the anode of the electric separator, the corrosion resistance of the samples is 35 % higher compared to the samples, which consists of fly ash, selected from the cathode or raw in an electric field (original fly ash).
Keywords: portland cement, mineral additives, fly ash, corrosion resistance, corrosion resistance coefficient.
Pages: 103-107.
For citation: Petrik, I. Yu.; Gubar, V. N.; Kornienko, S. V. Corrosion Resistance of Concrete with High Fly Ash Content. – Text : electronic. – In: Proceeding of the Donbas National Academy of Civil Engineering and Architecture. – 2017. – Issue 2017-4(126) Scientific and technical achievements of students of the construction and architectural industry. – Р. 103-107. – URL: https://donnasa.ru/publish_house/journals/vestnik/2017/2017-4(126)/st_24_petrik_gubar_kornienko.pdf (date of access: 19.11.2024). – ISSN 2519-2817.